ECS integrated fluorine pump solution
Solution Brief
The ECS integrated fluorinated pump utilizes parallel technology with fully variable-frequency compressors, combined with multi-channel electronic expansion valve and variable-frequency fluorinated pump technology, achieving the integration of two power modules; the system features multiple operating modes, automatically and seamlessly switching between modes based on outdoor temperature and indoor thermal load, maximizing the use of natural cold sources.
The ECS integrated fluorinated pump adopts a modular design, with a V-shaped integrated fluorinated pump outdoor unit, saving up to 50% more floor space than conventional flat outdoor units; the fluorinated pump system uses a tankless design, improving system stability in high-temperature environments. Suitable for most data center construction scenarios with rapidly changing indoor thermal loads, phased construction, water scarcity, and high requirements for natural cold source utilization and energy efficiency, it is also suitable for retrofitting indirect evaporative cooling air conditioning (AHU) data centers.
Key Parameters
Cooling capacity 80-360kW, compressor mode COP 3.5, natural cold source mode COP 22
Applicable Scenarios
Suitable for refrigeration applications requiring high temperature control accuracy, high sensible heat requirements, and high energy efficiency, especially in high-density cabinet environments such as data centers, cloud computing centers, medium and large-scale switch rooms, mobile data centers, and energy storage industries.
Advantageous Features
▪ Rapid Deployment: Integrated unit design, short on-site installation cycle, meets the needs of rapid on-site deployment;
▪ Air Isolation: No fresh air is introduced indoors. The indoor air handling unit and the outdoor condensing air handling unit are in one frame, but the air sides are completely isolated.
▪ Pre-fabrication: The evaporator and condenser connecting pipelines are short and pre-installed in the factory, eliminating on-site pipeline installation and avoiding adverse factors such as heat loss caused by excessively long on-site pipelines;
▪ High Efficiency and Energy Saving: High unit efficiency, full factory prefabrication design, reduces the actual delivery pPUE deviation; full variable frequency fluorine pump energy-saving air conditioning, ultimate natural cooling, PUE≤1.25;
▪ Intelligent Control: Automatically matches the operating mode according to the outdoor temperature and indoor heat load, resulting in better performance;
▪ Waterless Design: Multiple air supply methods.
![]() |
![]() |
| Side installation, same-floor layout, side supply and side return | Top installation, up and down layout, left supply and right return |